Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Input | Input Voltage | 200V(-10%) ~ 240V(+10%) Single-phase 380V(-10%) ~ 480V(+10%) Three-phase |
Input Frequency | 50 ~ 60Hz | |
Output | Control Method | VF Control |
Frequency Range | 0 ~ 300Hz | |
Frequency Resolution | 0.1Hz | |
Output Voltage | 0 ~ Input Voltage | |
Carrier Frequency | 1 ~ 10kHz | |
Speed Regulation Range | 1:50 | |
Overload Capacity | 150% rated current for 1 minute | |
Control Features | Torque Boost | 0.0% ~ 30.0% |
Acceleration/Decel Time | 0.0 ~ 6553.5s | |
VF Curve Modes | 0: Multi-point V/F,1: 2.0-exponent Curve,2: 1.7-exponent Curve 3: 1.2-exponent Curve | |
Jog Control | Jog frequency range: 0.00Hz~5.00Hz Jog acceleration/deceleration time: 0.0s~600.0s | |
DC Braking | Braking Frequency: 0.00Hz ~ Max Frequency Braking Time: 0.0s ~ 60.0s Braking Current: 0.0% ~ 100.0%" | |
Dynamic Braking | Built-in Braking Unit (Optional) Energy Consumption Braking Ratio: 0.0% ~ 100.0% | |
Advanced Functions | Installation | Support wall-mounted |
Protection class | IP20 | |
Working temperature | -10℃~+50℃; after exceeding 40℃, the derating will be reduced by 2% according to 1℃. | |
Cooling method | Forced air cooling | |
Humidity Installation environment | 20%~95%RH(condensation free)Less than 1000m; after exceeding 1000m, the amount will be reduced by 1% according to 100m. |
Installation | Built-in PID | Enables closed-loop process control systems (e.g., constant pressure, temperature control) through real-time feedback adjustment |
Built-in Multi- Speed & Simple PLC | Supports up to 16 preset speed segments via internal PLC programming or external control terminals | |
Programmed Acceleration /Deceleration Times | Provides 4 independent acceleration/deceleration time groups for flexible operation mode selection. Typical applications include staged startup/shutdown and load- adaptive speed regulation | |
Protections | Overheat/Overload/Overcurrent/Overvoltage/Stall Prevention/Short Circuit Protection | |
Swing Frequency Control | Swing Frequency Control (Textile Industry Applications) | |
Fixed-Length Control | Fixed-length Control | |
Frequency Reference | Digital Panel/Analog Input/Communication/PID | |
Command Sources | Panel Operation/Terminal Control/Communication | |
Fieldbus | RS485 Interface (MODBUS-RTU Protocol) |